Description | Voltage | Schematic | qty of coils | Coil Part Number | Max Bar | Max Tank Pressure Bar | Max Flow Rate LPM | IP Rating | Weight ea unpacked (kg) |
DG4V-3S-0B-M-U-A5-60 | 110VAC | 1 | 02-101725 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-0B-M-U-ED5-60 | 240VAC | 1 | 02-111261 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-0B-M-U-G5-60 | 12VDC | 1 | 507847 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-0B-M-U-H5-60 | 24VDC | 1 | 507848 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-0C-M-U-A5-60 | 110VAC | 2 | 02-101725 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-0C-M-U-ED5-60 | 240VAC | 2 | 02-111261 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-0C-M-U-G5-60 | 12VDC | 2 | 507847 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-0C-M-U-H5-60 | 24VDC | 2 | 507848 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-2A-M-U-A5-60 | 110VAC | 1 | 02-101725 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-2A-M-U-ED5-60 | 240VAC | 1 | 02-111261 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-2A-M-U-G5-60 | 12VDC | 1 | 507847 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-2A-M-U-H5-60 | 24VDC | 1 | 507848 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-2C-M-U-A5-60 | 110VAC | 2 | 02-101725 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-2C-M-U-ED5-60 | 240VAC | 2 | 02-111261 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-2C-M-U-G5-60 | 12VDC | 2 | 507847 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-2C-M-U-H5-60 | 24VDC | 2 | 507848 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-6C-M-U-A5-60 | 110VAC | 2 | 02-101725 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-6C-M-U-ED5-60 | 240VAC | 2 | 02-111261 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-6C-M-U-G5-60 | 12VDC | 2 | 507847 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-6C-M-U-H5-60 | 24VDC | 2 | 507848 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-8C-M-U-A5-60 | 110VAC | 2 | 02-101725 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-8C-M-U-ED5-60 | 240VAC | 2 | 02-111261 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-8C-M-U-G5-60 | 12VDC | 2 | 507847 | 350 | 100 | 40 | 65 | 2.2 | |
DG4V-3S-8C-M-U-H5-60 | 24VDC | 2 | 507848 | 350 | 100 | 40 | 65 | 2.2 |
-
Efficient control of greater hydraulic powers without increasing solenoid power consumption.
-
Installed cost and space savings from higher power/weight-and-size ratios.
-
Increases system efficiency; the result of improved manufacture of spools and bores
-
Installation flexibility resulting from choice of numerous combinations of solenoid connectors and locations
-
Multi-fluid capability without need to change seals.
-
Higher sustained machine productivity and higher uptime because of proven fatigue life and endurance, tested over 20 million cycles.
-
Solenoid coils can be changed quickly and easily without leakage from hydraulic system.
-
Compact, cost effective system design when used with Vickers® SystemStak™ valves and subplates.