Tech Specs
VISUAL / ELECTRIC SERIES |
||||||
PART NUMBER | STYLE | TYPE | FUNCTION | THREAD | BAR RATING | SUITS FILTER |
1E | SWITCH | VISUAL / ELECTRIC | DIFFERENTIAL | 1/2" BSP | 1.2 | MPS-(051, 071, 101) |
E6 | SWITCH | VISUAL / ELECTRIC | DIFFERENTIAL | 1/2" BSP | 2 | MPS-(051, 071, 101), LMP, MSH |
E7 | SWITCH | VISUAL / ELECTRIC | DIFFERENTIAL | 1/2" BSP | 5 | FHM, FHP, FMM, FMP |
E8 | SWITCH | VISUAL / ELECTRIC | DIFFERENTIAL | 1/2" BSP | 7 | FHM, FHP |
E9 | SWITCH | VISUAL / ELECTRIC | DIFFERENTIAL | 1/2" BSP | 10 | FHM, FHP |
ELECTRIC SERIES |
||||||
PART NUMBER | STYLE | TYPE | FUNCTION | THREAD | BAR RATING | SUITS FILTER |
E1 | SWITCH | ELECTRIC | N/O & N/C contacts | 1/4" BSP | 20 KPA | SF2-250 & SF2-500 Series |
EC | SWITCH | ELECTRIC | N/C contacts | 1/8" BSP | 1.3 | MPF, MPH, MPS-(050, 070, 100, 200, 300) |
EQ | SWITCH | ELECTRIC | N/O contacts | 1/8" BSP | 0.6 | MPH |
ER | SWITCH | ELECTRIC | N/O contacts | 1/8" BSP | 1.3 | MPF, MPH, MPS-(050, 070, 100, 200, 300) |
N6 | SWITCH | ELECTRIC | DIFFERENTIAL | 1/2" BSP | 2 | LMP, MPS-(051, 071, 101), MSH |
N7 | SWITCH | ELECTRIC | DIFFERENTIAL | 1/2" BSP | 5 | FHM, FHP, FMM, FMP |
N8 | SWITCH | ELECTRIC | DIFFERENTIAL | 1/2" BSP | 7 | FHM, FHP, FMM, FMP |
N9 | SWITCH | ELECTRIC | DIFFERENTIAL | 1/2" BSP | 10 | FHM, FHP |
VISUAL SERIES |
||||||
PART NUMBER | STYLE | TYPE | FUNCTION | THREAD | BAR RATING | SUITS FILTER |
1V | POPUP | VISUAL | DIFFERENTIAL | 1/2" BSP | 1.2 | MPS-(051, 071, 101) |
V6 | POPUP | VISUAL | DIFFERENTIAL | 1/2" BSP | 2 | LMP, MSH, MPS-(051, 071, 101) |
V7 | POPUP | VISUAL | DIFFERENTIAL | 1/2" BSP | 5 | FHM, FHP, FMM, FMP |
V8 | POPUP | VISUAL | DIFFERENTIAL | 1/2" BSP | 7 | FHM, FHP, FMM, FMP |
V9-1 | POPUP | VISUAL | DIFFERENTIAL | 1/2" BSP | 10 | FHM, FHP |
VR | GAUGE | VISUAL | COLOUR CODED | 1/8" BSP | 0 – 6 | MPF-184, MPT, MPH, MST, MPS-(050, 070, 100, 200, 300) |
V | GAUGE | VISUAL | SUCTION | 1/4" BSP | 20 KPA | SF2-250 & SF2-500 SERIES |
V1 | GAUGE | VISUAL | COLOUR CODED | 1/8" BSP | 0 – 6 | MPF, MPH |
VS | GAUGE | VISUAL | SUCTION | 1/8" BSP | 0 – 76 cm Hg | MPS-(050, 070, 100, 200, 300) |
VT | GAUGE | VISUAL | COLOUR CODED | 1/8" BSP | 0 – 3 bar | MPH |
Z1 | POPUP | VISUAL | DIFFERENTIAL | 1/2" BSP | 1.2 | MPS-(051, 071, 101) |
Features and Benefits | Performance | |
MP Filtri indicators are available as Clogging (monitoring the increase of pressure on the inlet port of the filter) or Differential (monitoring the difference of pressure between inlet and outlet ports). | Temperature Range | – 35 C to + 110 C |
A guarantee of maintenance to the correct ISO 4406 contamination class can be achieved through the use of filters utilizing clogging or differential indicators. | Maximum Working Pressure | Up to 420 bar |
The trip threshold of the indicator must be selected taking into account the maximum differential pressure of the filter element and the trip pressure of the bypass valve, if incorporated in the filter. | Construction | Brass |
Available in a number of styles and configurations including Gauges, Popup style, Electric switching and combinations of Electric and visual. | Fluid Compatibility | Mineral & synthetic oils, water based emulsions |
Install an indicator and take the guess work out of deciding when to change elements and save unnecessary costs of changing elements too soon. | Indicators | Clogging & Differential |